Aqua Lung Mistral Mouthpiece Manuel de maintenance technique - Page 8

Parcourez en ligne ou téléchargez le pdf Manuel de maintenance technique pour {nom_de_la_catégorie} Aqua Lung Mistral Mouthpiece. Aqua Lung Mistral Mouthpiece 14 pages.
Également pour Aqua Lung Mistral Mouthpiece : Manuel d'entretien (14 pages)

Aqua Lung Mistral Mouthpiece Manuel de maintenance technique
8
SYMPTOM
External Leak
Reduced air fl ow or a signifi cant
general increase in breathing
resistance in the complete regulator
Impossible to inhale or exhale from the
complete regulator
Water enters the mouthpiece
during inhalation
Table 1: Troubleshooting Guide
POSSIBLE CAUSE
3. The connector or valve support o-rings (7)
are extruded, worn or damaged.
2. The mouthpiece body (10) is cracked.
3. The corrugated hoses (1) are worn or
damaged.
4. The corrugated hose clamping bands (2)
are damaged or improperly installed.
1. The cylinder valve is not completely open.
2. The cylinder valve needs servicing.
3. The fi rst stage fi lter(10) is blocked.
4. The cylinder is empty.
1. The valve supports (8) have been fi tted
the wrong way in the mouthpiece.
2. The mouthpiece has been fi tted back
backwards to the corrugated hoses.
3. The cylinder valve is not open.
4. The cylinder is empty.
1. Mouthpiece (14) pierced or broken.
2. Diaphragm damaged.
3. The connector or valve support o-rings (7)
are extruded, worn or damaged.
4. The corrugated hose clamping bands (2)
are damaged or improperly installed.
5. The corrugated hoses (1) are worn or
damaged.
TREATMENT
1. Replace the o-rings
2. Replace the mouthpiece body
3. Replace the corrugated hoses
4. Re-install or replace the clamping
bands
1. Open the valve and check the
cylinder pressure
2. Try another cylinder
3. See the Mistral First Stage Trouble
Shooting Guide
4. Charge the cylinder
1. Disassemble and refi t following the
correct procedure
2. Disassemble and refi t following the
correct procedure
3. Open the valve
4. Charge the cylinder
1. Replace the mouthpiece
2. See the Mistral Second Stage
Trouble Shooting Guide
3. Replace the o-rings
4. Re-install or replace the
clamping bands
5. Replace the corrugated hoses