CALIBRATION PROCEDURE
Verify that the power is on by checking that the front panel POWER ON light is lit.
Set SAP Channel Demod:
Move the shorting block on jumper JU1 from position 1-2 to position 3-4. This will
disconnect the audio signal coming out of the tuner module from the signal path, and
will let the SAP demod circuit free-run.
Connect a frequency counter to either side of C41. The frequency counter should
measure 78.6 kHz (±0.2 kHz). If necessary, adjust R51 (VCO ADJUST) until a
frequency of 78.6 kHz is measured. Restore JU1 to the 1-2 position to reconnect the
tuner module output.