2.Set Up/ Installlation

The reactor 1000 has two hose connections for 16/18 mm hose and may be used
externally or internally.

- Mounting inside of the aquarium

The included holding system allows the easy fixing of the reactors at or inside of the
aquarium. The holder is mounted on a vertical or horizontal glass stripe and secured
with the 2 screws.

- Mounting outside of the aquarium

The reactor 1000 may be mounted at a wall or inside the aquarium cabinet. For this, the
holder (6) is removed and the holding plate (7) is directly screwed to the wall or the
cabinet. If the reactor 1000 is used externally, make sure, that both water connections
are tightened and the O-rings (9) are correctly mounted.
Now both holding clamps (7) are mounted and the reactor 1000 is pressed into the
clamps.
Water inlet. The water inlet is connected to the upper hose connection of the reactor
1000 (2). For the water supply, a separate pump ( min 1.000 l/hr , 250 gph) or the water
outlet of a canister filter may be used. A stronger circulation improves the solution of the
carbon dioxide. If the circulation pump is too strong, the reactor can be mounted in a
bypass.
Water outlet. The water outlet is connected to the lower hose connection of the reactor
1000 and with a hose 12/16 mm, ½"
The CO2 is connected to the pressure fitting (3). Make sure, that a non return valve is
mounted between the reactor and the bubble counter of the CO2-unit. The CO2 is
directed downwards inside of the reactor with a hose. By this counter current flow, the
dissolving of the gas is optimised. The Bactoballs give an extra turbulence.
False gas removal. The air in the reactor reactor can be removed with the valve (4)
during starting. Also the false gas which can accumulate in the reactor during operation
can be absorbed by opening the tap for a short time.
Please do always care that the hoses do not bend.
technical data
unit
reactor
water connection port:
CO2-connection:
water flow:
set up:
back to the aquarium.
1000
Art. No:
12/16 mm
6/4 mm
min 1..000 l/std
internally or externally
71113