Avonic AV-CON300 Manuel de l'utilisateur - Page 9

Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} Avonic AV-CON300. Avonic AV-CON300 16 pages. Ptz camera controller
Également pour Avonic AV-CON300 : Manuel de l'utilisateur (13 pages), Manuel de démarrage rapide (2 pages)

Wire 2 is optional

Phoenix connector

The cameras assigned to channel 1 can also be controlled using the 5-pin Phoenix connector. The
connection diagram is as follows:
Picture

Connecting multiple cameras by RS232

The VISCA protocol supports up to 7 cameras and can be cascaded by connecting RS232-out from
each camera to RS232-in of the following according to the picture:
www.avonic.eu
1
1
2
2
3 TX
3 TX
4 GND
4 GND
5
5 RX
6 RX
6
7
7
8
8
Function
1. RS485 (Y)
2. RS485 (Z)
3. RS232 GND (G)
4. RS232 TX (B)
5. RS232 RX (A)
9