Dell Poweredge 6100/200 Manuel du matériel - Page 10

Parcourez en ligne ou téléchargez le pdf Manuel du matériel pour {nom_de_la_catégorie} Dell Poweredge 6100/200. Dell Poweredge 6100/200 15 pages. Microprocessor replacement
Également pour Dell Poweredge 6100/200 : Manuel complémentaire (4 pages)

Dell Poweredge 6100/200 Manuel du matériel
8
Dell PowerEdge 6100/200 System Microprocessor Replacement
M
icroprocessor and Heat Sink
The computer can have up to four microprocessors installed.
microprocessor
socket
Figure 6. Microprocessor Configuration
To remove the microprocessor/heat sink assembly, follow these steps:
1. Remove the left computer cover.
2. Remove the support panel and the appropriate microprocessor module.
3. Remove the microprocessor securing clip from the microprocessor/heat
sink assembly (see Figure 7).
WARNING: The microprocessor chip can get extremely hot during
system operations. Be sure the chip has had sufficient time to cool
before touching it.
microprocessor
securing clip
heat sink
thermal interface pad
(attached to the heat sink)
microprocessor
pin-1 corner of
socket
front tab