Dell PowerEdge C6100 Utiliser l'instruction - Page 47

Parcourez en ligne ou téléchargez le pdf Utiliser l'instruction pour {nom_de_la_catégorie} Dell PowerEdge C6100. Dell PowerEdge C6100 48 pages. Poweredge series
Également pour Dell PowerEdge C6100 : Manuel du portefeuille (27 pages)

Dell PowerEdge C6100 Utiliser l'instruction

BIOS Version Information

The BIOS enables the system interface to the BMC and logs this event to the BMC early in POST.
BIOS version information is located in the event record, bytes 15 and16.
Table 1-39. POST Start Event
Byte
Item
1–2
Record ID
3
Record Type
4–7
Timestamp
8–9
Generator ID
10
Event Message Format Version
11
Sensor Type
12
Sensor Number
13
Event Direction/Event Type
14
Event Data 1
15
Event Data 2
16
Event Data 3
Example:
SEL list command:
ipmitool sel get 9
This indicates that the BIOS version is V1.1.
Data
0x01 (BIOS)
0x04 (IPMI 1.5)
0xC1 (OEM reserved)
0x81 (BIOS start)
0x70 (OEM)
0xA0
0x01 (BIOS major version)
0x01 (BIOS minor version)
Using the Baseboard Management Controller
47