Dell PowerEdge C6100 인스트럭션 사용 - 페이지 47

{카테고리_이름} Dell PowerEdge C6100에 대한 인스트럭션 사용을 온라인으로 검색하거나 PDF를 다운로드하세요. Dell PowerEdge C6100 48 페이지. Poweredge series
Dell PowerEdge C6100에 대해서도 마찬가지입니다: 포트폴리오 매뉴얼 (27 페이지)

Dell PowerEdge C6100 인스트럭션 사용

BIOS Version Information

The BIOS enables the system interface to the BMC and logs this event to the BMC early in POST.
BIOS version information is located in the event record, bytes 15 and16.
Table 1-39. POST Start Event
Byte
Item
1–2
Record ID
3
Record Type
4–7
Timestamp
8–9
Generator ID
10
Event Message Format Version
11
Sensor Type
12
Sensor Number
13
Event Direction/Event Type
14
Event Data 1
15
Event Data 2
16
Event Data 3
Example:
SEL list command:
ipmitool sel get 9
This indicates that the BIOS version is V1.1.
Data
0x01 (BIOS)
0x04 (IPMI 1.5)
0xC1 (OEM reserved)
0x81 (BIOS start)
0x70 (OEM)
0xA0
0x01 (BIOS major version)
0x01 (BIOS minor version)
Using the Baseboard Management Controller
47