Dell PowerEdge R820 Manuel de démarrage - Page 7

Parcourez en ligne ou téléchargez le pdf Manuel de démarrage pour {nom_de_la_catégorie} Dell PowerEdge R820. Dell PowerEdge R820 9 pages. Poweredge series
Également pour Dell PowerEdge R820 : Installation (2 pages), Installation (2 pages), Manuel technique (50 pages), Manuel du portefeuille (27 pages)

Dell PowerEdge R820 Manuel de démarrage
Power
AC Power Supply (per power supply)
Wattage
Heat dissipation
NOTE: Heat dissipation is calculated using
the power supply wattage rating.
Voltage
NOTE: This system is also designed to be
connected to IT power systems with a
phase to phase voltage not exceeding 230 V.
DC Power Supply (per power supply) (when
available)
Wattage
Heat dissipation
NOTE: Heat dissipation is calculated using
the power supply wattage rating.
Voltage
Battery
Coin-cell battery
Physical
Height
Width
With rack latches
Without rack latches
Depth (includes bezel)
Weight (maximum)
Weight (empty)
Environmental
NOTE: For additional information about environmental measurements for specific system configurations, see
dell.com/environmental_datasheets.
Temperature
Operating
750 W or 1100 W
2891 BTU/hr maximum (750 W power supply)
4100 BTU/hr maximum (1100 W power supply)
100–240 V AC, autoranging, 50/60 Hz
1100 W
4416 BTU/hr maximum
–(48–60) V DC
3 V CR2032 Lithium coin cell
86.8 mm (3.41 inch)
482.4 mm (18.98 inch)
434 mm (17.08 inch)
810.6 mm (31.91 inch)
29.5 kg (65.036 lb)
22.45 kg (49.494 lb)
Continuous operation: 10 °C to 35 °C at 10% to 80% relative
humidity (RH), with 26 °C max dew point. De-rate maximum
allowable dry bulb temperature at 1 °C/300 m above 900 m (1 °F
per 550 ft).
7