Dell PowerEdge R820 Manuel de démarrage - Page 8
Parcourez en ligne ou téléchargez le pdf Manuel de démarrage pour {nom_de_la_catégorie} Dell PowerEdge R820. Dell PowerEdge R820 9 pages. Poweredge series
Également pour Dell PowerEdge R820 : Installation (2 pages), Installation (2 pages), Manuel technique (50 pages), Manuel du portefeuille (27 pages)
Environmental
Storage
Relative humidity
Operating
Storage
Maximum vibration
Operating
Storage
Maximum shock
Operating
Storage
Altitude
Operating
Storage
Airborne Contaminant Level
Class
8
NOTE: For information on supported expanded operating
temperature range and configurations, see support.dell.com/
manuals.
–40 °C to 65 °C (–40 °F to 149 °F) with a maximum temperature
gradation of 20 °C per hour
20% to 80% (noncondensing) at a maximum wet bulb
temperature of 29 °C (84.2 °F)
5% to 95% at a maximum wet bulb temperature of 38 °C (100.4 °F)
0.26 Grms at 5 Hz–350 Hz (all operation orientations)
1.87 Grms at 10 Hz–500 Hz for 15 min (all six sides tested)
One shock pulse in the positive z axis (one pulse on each side of
the system) of 31 G for 2.6 ms in the operational orientation
Six consecutively executed shock pulses in the positive and
negative x, y, and z axes (one pulse on each side of the system)
of 71 G for up to 2 ms
Six consecutively executed shock pulses in the positive and
negative x, y, and z axes (one pulse on each side of the system)
of 32 G faired square wave pulse with velocity change at 270
inches/second (685 centimeters/second)
–15.2 m to 3048 m (–50 ft to 10,000 ft)
NOTE: For altitudes above 2950 ft, the maximum operating
temperature is derated 1ºF per 550 ft.
–15.2 m to 10,668 m (–50 ft to 35,000 ft)
G1 as defined by ISA-S71.04-1985