Figure 1. Removing the Filler Plug
7
Angle the RAC card so that the NIC connector inserts through the back-panel RAC card
opening, and then straighten the card. See Figure 2.
8
Install the RAC card:
Hold the card by its edges with the holes in the corners of the card aligned with the four
a
plastic standoffs on the system board. See Figure 2.
Carefully press the back edge of the card onto the RAC card connector on the system
b
board, until the clips on the plastic standoffs snap over that end of the card. See Figure 2.
9
Press down on the front edge of the card until the remaining two plastic standoffs fit over the
card edge.
10
Reinstall the back fan bracket (if removed in step 6).
11
Reinstall the two memory module fans (if removed in step 5).
12
Reinstall the memory cooling shroud (if removed in step 4).
13
Close the system.
14
Reconnect the system and peripherals to their power sources, and turn them on.