Dell Brocade VDX 6940 Manuel de configuration - Page 7
Parcourez en ligne ou téléchargez le pdf Manuel de configuration pour {nom_de_la_catégorie} Dell Brocade VDX 6940. Dell Brocade VDX 6940 12 pages. Ps series
2.3
Configure management ports
sw0# configure
sw0(config)# interface Management 1/0
sw0(config-Management-1/0)# ip address <ip address/mask>
sw0(config-Management-1/0)# exit
2.4
Convert 40GbE ports to 10GbE mode
Note: For this example, physical ports 1–5 are converted from 40GbE mode to 4 x 10GbE mode.
sw0(config)# interface FortyGigabitEthernet 1/0/1-5
sw0(conf-if-fo-1/0/1-5)# shutdown
sw0(conf-if-fo-1/0/1-5)# exit
sw0(config)# hardware
sw0(config-hardware)# connector 1/0/1-5
sw0(config-connector-1/0/1-5)# sfp breakout
sw0(config-connector-1/0/1-5)# end
2.5
Configure port channel
sw0#configure
sw0(config)#interface Port-channel 1
sw0(config-Port-channel-1)# mtu 9216
sw0(config-Port-channel-1)# switchport
sw0(config-Port-channel-1)# switchport mode trunk
sw0(config-Port-channel-1)# qos flowcontrol tx off rx on
sw0(config-Port-channel-1)# speed 40000
sw0(config-Port-channel-1)# no shutdown
sw0(config-Port-channel-1)# exit
2.6
Configure ports for LAG
Note: For this example, ports 35 and 36 are used for the LAG interconnect.
sw0(config)# interface FortyGigabitEthernet 1/0/35-36
sw0(conf-if-fo-1/0/35-36)# no fabric isl enable
sw0(conf-if-fo-1/0/35-36)# no fabric trunk enable
sw0(conf-if-fo-1/0/35-36)# channel-group 1 mode active type brocade
sw0(conf-if-fo-1/0/35-36)# no cee
sw0(conf-if-fo-1/0/35-36)# no lldp disable
sw0(conf-if-fo-1/0/35-36)# no shutdown
sw0(conf-if-fo-1/0/35-36)# exit
7