Dell Brocade VDX 6940 Panduan Konfigurasi - Halaman 7

Jelajahi secara online atau unduh pdf Panduan Konfigurasi untuk Beralih Dell Brocade VDX 6940. Dell Brocade VDX 6940 12 halaman. Ps series

Dell Brocade VDX 6940 Panduan Konfigurasi
2.3

Configure management ports

sw0# configure
sw0(config)# interface Management 1/0
sw0(config-Management-1/0)# ip address <ip address/mask>
sw0(config-Management-1/0)# exit
2.4

Convert 40GbE ports to 10GbE mode

Note: For this example, physical ports 1–5 are converted from 40GbE mode to 4 x 10GbE mode.
sw0(config)# interface FortyGigabitEthernet 1/0/1-5
sw0(conf-if-fo-1/0/1-5)# shutdown
sw0(conf-if-fo-1/0/1-5)# exit
sw0(config)# hardware
sw0(config-hardware)# connector 1/0/1-5
sw0(config-connector-1/0/1-5)# sfp breakout
sw0(config-connector-1/0/1-5)# end
2.5

Configure port channel

sw0#configure
sw0(config)#interface Port-channel 1
sw0(config-Port-channel-1)# mtu 9216
sw0(config-Port-channel-1)# switchport
sw0(config-Port-channel-1)# switchport mode trunk
sw0(config-Port-channel-1)# qos flowcontrol tx off rx on
sw0(config-Port-channel-1)# speed 40000
sw0(config-Port-channel-1)# no shutdown
sw0(config-Port-channel-1)# exit
2.6

Configure ports for LAG

Note: For this example, ports 35 and 36 are used for the LAG interconnect.
sw0(config)# interface FortyGigabitEthernet 1/0/35-36
sw0(conf-if-fo-1/0/35-36)# no fabric isl enable
sw0(conf-if-fo-1/0/35-36)# no fabric trunk enable
sw0(conf-if-fo-1/0/35-36)# channel-group 1 mode active type brocade
sw0(conf-if-fo-1/0/35-36)# no cee
sw0(conf-if-fo-1/0/35-36)# no lldp disable
sw0(conf-if-fo-1/0/35-36)# no shutdown
sw0(conf-if-fo-1/0/35-36)# exit
7