Dell Force10 S4810 Manuel de déploiement - Page 28
Parcourez en ligne ou téléchargez le pdf Manuel de déploiement pour {nom_de_la_catégorie} Dell Force10 S4810. Dell Force10 S4810 36 pages. Dell force10 s4810 switch
Également pour Dell Force10 S4810 : Manuel de démarrage rapide (27 pages), Manuel de configuration (17 pages), Manuel de configuration (17 pages)
controller
Specify the OpenFlow controller configuration that the OpenFlow instance uses to establish a connection.
Z-Series, S4810
Syntax
controller {controller-id}{ip-address}[port port-number]tcp
Parameter
controller-id
ip-address
port-number
port
Defaults
Default port number for the TCP connection is 6633.
Command Modes
OPENFLOW INSTANCE
Command History
Version 9.1(0.0)
Usage
The controller number must be entered as 1 to enable OpenFlow. Currently, only TCP
Information
connection is supported.
Related
openflow of-instance
Commands
debug openflow packets
Enable debugging for OpenFlow packets.
Z-Series, S4810
Syntax
debug openflow packets {packet-type packet-type} of-instance
{of-id}
Parameter
{packet-type
packet-type }
28
Enter the controller number (must be 1).
Enter the IP address of the controller.
Enter the keyword port followed by the port number to use for the
connection. Range is 1 to 65535.
Introduced on Z9000 and S4810.
Create or modify an OpenFlow instance.
Enter the keyword packet-type followed by one of the following
packet types:
all
Enable debugging for all packets.
barrier-reply
Enable debugging for barrier-reply packets.
barrier-request
Enable debugging for barrier-request
packets.
echo-reply
Enable debugging for echo-reply packets.
echo-request
Enable debugging for echo-request packets.
error
Enable debugging for error packets.