Dell Force10 S4810 Manuel de configuration - Page 8

Parcourez en ligne ou téléchargez le pdf Manuel de configuration pour {nom_de_la_catégorie} Dell Force10 S4810. Dell Force10 S4810 17 pages. Dell force10 s4810 switch
Également pour Dell Force10 S4810 : Manuel de démarrage rapide (27 pages), Manuel de déploiement (36 pages), Manuel de configuration (17 pages)

Dell Force10 S4810 Manuel de configuration
2.4

Configure route for OOB management port (optional)

Force10(conf)#management route X.Y.Z.0 /24 A.B.C.1
Note: X.Y.Z.0 is the network your management system is connecting from and A.B.C.1 is the gateway for
the switch. If your management system is on the same subnet as the switch, the previous step may be
omitted. The example above assumes a class C subnet mask.
2.5

Configure login credentials

FTOS(conf)#username admin privilege 15 password 0 yourpassword
FTOS(conf)#enable password level 15 0 yourpassword
2.6

Enable iSCSI optimization feature

This feature is enabled when EqualLogic arrays are connected. It automatically performs the following:
• Configures jumbo frames to 12k on all ports.
• Disables unicast storm.
• Enables spanning tree portfast on ports connected to EqualLogic arrays.
• Configures flowcontrol on all ports (rx on tx off).
Note: Spanning tree portfast must be manually configured for host facing ports. Refer to section 2.8.
FTOS#configure
FTOS(conf)#iscsi enable
FTOS(conf)#exit
2.7

Enable switch ports

Option 1: You can enable the array or host facing ports individually.
Note: This method is more secure than Option 2.
FTOS#configure
FTOS(conf)#interface tengigabitethernet 0/0
FTOS(conf-if-te-0/0)#switchport
FTOS(conf-if-te-0/0)#no shutdown
FTOS(conf-if-te-0/0)#exit
FTOS(conf)#exit
8
SCG1000
Force10 S4810 Configuration Guide