CAUTION
To prevent accidental starting:
Engine must be turned off and cool, and spark plug
wire must be removed from spark plug before
checking and adjusting engine or equipment.
MAINTENAN E AND STORAGE SAFETY
1. Always allow muffler to cool before filling fuel tank.
2. When storing for over one (1) month, use gas stabilizer
in fuel.
3. Do not fill gas tank indoors or when engine is running or
is hot.
4. The gear case has four (4) oz. of grease installed at the
factory. It is recommended that once a year the gear
case be split and the grease level checked. Add grease
only if level of grease is below top of the gears. DO NOT
OVERFILL.
5. For cold weather operation, store the unit in a cool
environment. Transferring the unit from a warm to a cold
place can cause the build up of harmful condensation.

MAINTENANCE AND STORAGE

ENGINE MAINTENAN E
Do not operate auger before reading the engine
manual provided in the parts packet.
Engine can overheat and become damaged if debris
blocks the cooling fins or recoil housing.
Refer to the engine manual included in your parts packet
for information on engine maintenance. Your engine manual
provides detailed information and a maintenance schedule
for performing the following tasks:
1. Check oil level every five (5) operating hours and before
each use.
2. Change oil after first two (2) operating hours and every
25 operating hours thereafter, more often if operated in
extremely dusty or dirty conditions. Change oil while
engine is still warm from recent running.
3. Frequently remove dirt and debris from cooling fins, air
intake screen, levers and linkage. This will help ensure
adequate cooling and correct engine speed.
4. Check air cleaner.
Never run engine without complete air cleaner
installed on engine.
5. Check spark plug yearly or every 100 operating hours.
6. Check engine and auger often for loose nuts and bolts.