Allmatic AS24 Manuel d'installation - Page 4
Parcourez en ligne ou téléchargez le pdf Manuel d'installation pour {nom_de_la_catégorie} Allmatic AS24. Allmatic AS24 10 pages. Control unit for 1-2 motors 24vdc
6. Setting the wing stroke
This procedure must ONLY be carried out by the installer and ONLY during the setting up of the system. If you do not utilize any transmitter, it is
necessary to use the Red key (P1) and BLUE (P2) present on the card or with P.P and PED buttons. Then you must carry out the following procedure:
1.
Close the door, see point 4, to move the wings manually.
2.
Select if the control unit must work one wing (DIP 8 on ON) or 2 wings (DIP 8 on OFF).
3.
Put the DIP 1 on OFF.
4.
Put the DIP 2 on ON. The flashing light blinks slowly.
WARNING: during the learning of the strokes, the phase shift of the wings is also set.
Setting of the wings number
2 wings door
Setting of the wings stroke
Dipswitch position
1
Press and release the 1° memorized key or
2
press the RED key (P1)
If you are using a single wing gate, pass to the point 4
Once the wing 1 reaches the desired phase
3
shit, press and release the 2° memorized key or
the BLUE key (P2)
Once
the
gate
4
completely open it re – closes automatically.
Once
the
gate
5
completely closed the flashing light emits 4
blinking
Dipswitch position
6
7. Adjusting threshold of the ampere sensor operating
This procedure must ONLY be carried out by the installer and ONLY during the put in function of the system. For a correct programming, before
carrying out the modifications, bring always back the door to the totally closed position.
Repeat the measure
of the torque
With the wing in movement check,
through a dynamometer, the pushing
force at the edge of the wing.
Repeat the measure
of the torque
6-1622372
rev.5 04/02/2016
1 wing door
The flashing light starts
to blink lightly
reaches
the
position
of
reaches
the
position
of
The learning is ended.
The control unit is ready to work regularly.
It is possible to turn the RUNNING AMP.
SENSE trimmer in clockwise sense to
increase the threshold of the ampere
sensor.
The edge of the ampere sense
is too low.
The edge of the ampere sensor
is too high.
It is possible to turn the RUNNING
AMP.SENS. trimmer in anti – clockwise
sense to lower the threshold of the
ampere sensor.
ITA
ENG
The wing 1 begins
to open.
The wing 2 begins
to open.
The gate re – closes.
The learning has had a successful conclusion.
FRA
ESP
DEU
POR
RUNNING
AMP.SENS
RUNNING
AMP.SENS
Pag 4 di 10