General Maintenance

IMPORTANT!
Failure to carry out routine maintenance and/or leaving the pump
with reduced/no flow rate for long periods will result in a shorter pump life and
will invalidate the warranty. It is recommended to disconnect your pump and
clean the impeller and pipework monthly.
Disconnect the mains electricity supply before attempting any installation /
maintenance of any kind.
1. Unfix the pegs and take the unit out of water.
2. Hold the main part of the water pump with one hand and rotate the buoy
counterclockwise with the other hand to separate the two.
3. Rotate the unit's body counterclockwise and remove the fixing frame.
4. Push the lock clip and rotate along the joint to separate the water filter cover
from the lower shell of the main body.
5. Loosen two screws (as shown in the image below) to access the impeller.
Ensure that the plastic propeller part of the impeller is attached to the ceramic
part and that they have not come apart or split. If this is the case you need to
replace your impeller. Wash parts with fresh water carefully.
6. Clean it carefully under running water.
7. Re-assemble.