SECTION 4 – MAINTENANCE &TROUBLESHOOTING
4-1. Routine Maintenance
3 Months
Replace unreadable labels
Clean and tighten weld terminals
6 Months
Blow out or vacuum inside.
4-2. Circuit Breakers CB1 And CB2
1
2
4-3. Unit Overload
If unit is used beyond capacity (excessive wire feed, shorted output, etc.), wire feeds but is not energized. Release gun
trigger to reset this condition.
OM-1317 Page 18
OR
4
Y Disconnect power
before maintaining.
Repair or replace
cracked weld cable
Remove drive roll and
carrier. Apply light coat
of oil or grease to drive
motor shaft.
3
.
Maintain more often
during severe conditions.
1
Circuit Breaker CB2
CB2 protects Remote 14 recep-
tacle RC1 from overload.
2
Circuit Breaker CB1
If CB1 opens, wire feeding stops.
3
Welding Gun (Not Included)
Check gun liner for blockage or
kinks.
4
Wire Drive Assembly
Check for jammed wire, binding
drive gear or misaligned drive rolls.
Allow cooling period and reset
breaker. Close door.