Miller I-24 Manuel du propriétaire - Page 23

Parcourez en ligne ou téléchargez le pdf Manuel du propriétaire pour {nom_de_la_catégorie} Miller I-24. Miller I-24 36 pages.

Miller I-24 Manuel du propriétaire

4-2. Optional Side Panel Controls

SECTION 5 – MAINTENANCE & TROUBLESHOOTING

5-1. Routine Maintenance

14-Pin Cord
1
2
3
Replace
Unreadable
Labels
Gun Cable
Clean
Drive
Rolls
Y Disconnect power before maintaining.
3 Months
Repair Or
Replace
Cracked
Weld Cable
Gas Hose
6 Months
OR
1
Preflow Control
Control sets time gas flows before
welding wire is energized. Time
range is 0 to 5 seconds.
2
Postflow Control
Control sets time gas flows after
completion of burnback. Time
range is 0 to 5 seconds.
3
Spot Time Control
Factory set for 0.25 to 5 seconds of
spot time. Rotating knob fully
counterclockwise
selects
untimed continuous weld.
Close side door.
Ref. 801 923-C / Ref. 186 589
Clean And
Tighten
Weld
Terminals
Replace
Cracked
Parts
Blow Out Or Vacuum
Inside,
During Heavy Service,
Clean Monthly
OM-186 895 Page 19