4-14. Selecting Synergic Pulsed MIG Welding

Set Synergic Pulsed MIG welding process
using P3 push button.
Synergic Pulsed MIG welding is a high qu-
ality welding process that produces very
little spatter. This process works well on thin
metals such as stainless steel and alumin-
um.
In Synergic Pulsed MIG mode, the operator
may need to adjust welding data (wire type,
wire diameter, and gas type) and only one
weld parameter. Generally, wire feed speed
is adjusted and the synergic process auto-
matically sets appropriate weld voltage.
Synergic welding also sets many secon-
dary welding parameters automatically for
improved weld quality.
During Setting:
D1 value is the default voltage setting
(range is defined by wire type, wire diame-
ter and gas type selection).
D2 value is the default current setting
(range is defined by wire type, wire diame-
ter and gas type selection).
E1
D1
P3
P4
P5
During Synergic MIG Welding:
D1 value is Measured Welding Voltage in
Volts.
D2 Value is Measured Welding Amperage
in Amperes.
Select wire type using P4 push button.
Select wire diameter using P5 push button.
Select gas using P6 push button.
Select trigger mode using P7 push button.
See wire feeder manual for all the remaining
Synergic MIG settings.
Setting Cooler Status (see Section 4-3)
Setting Synergic Double Pulsed MIG
Welding
Some metals weld better using the Synerg-
ic Double Pulsed Welding process due to
the unique pulsing of the welding arc. Heat
generated in the workpiece is generally
lower and the arc characteristics produce a
better weld bead appearance especially on
aluminum. The Synergic Double Pulsed
MIG process allows control all parameters
to produce high quality welds on aluminum.
D2
E2
P6
P7
.
Incorrect settings in Synergic Double
Pulsed Welding process can result in a
program with undesirable weld charac-
teristics. Setup should only be used by
operators familiar with various welding
processes and parameters. In certain
applications standard Pulsed MIG
welding may be preferred.
Press P2 to enter setup menu.
D1 displays DP.
D2 default setting is OFF.
Use E2 to change D2 value to ON. This set-
ting will enable or disable Double Pulsed
MIG Synergic welding.
.
On power source, only Double pulse
enabling and disabling is possible. All
the remaining Double Pulse settings
are made on the wire feeder (see Wire
Feeder manual). From the wire feeder
it is possible to recall Synergic MIG,
Synergic Pulsed MIG and Synergic
Double Pulsed MIG programs (see
Wire Feeder manuals).
Ref. 956142645-5-5
OM-244 243 Page 25