Maintenance

The Skyline 70 Fluid Head offers high quality surface coatings.
Miller recommends keeping the Fluid Head clean at all times by
using soft brushes and lint free cloth to wipe over the surfaces.
• Do not immerse the Fluid Head in any liquid.
• Do not use stiff brushes, abrasives, harsh detergents and
solvents.

Battery Replacement

The Skyline 70 Fluid Head uses a single GP23A type - 12 Volt
battery for Illumination. Miller recommends the following batteries
to provide long life performance – GP23A, Duracell MN21/23 or
Vinnic L1028.
1 Using a Phillips Head #1 screw driver, remove the RETAINING
SCREWS and the BATTERY DOOR.
2 Using a small flat screw driver remove the battery.
3 Align the new battery as shown on the back of the BATTERY
DOOR and place into the BATTERY HOUSING, then push down
the battery into place. A small flat screw driver may be used to
push down the battery into the BATTERY HOUSING.
4 Align the BATTERY DOOR into the body then tighten the
screws lightly.
Battery
9
Illumination Button
Battery Housing
Battery Cover
Retaining Screws
Fig. 8