Aquasana AQ-SFRO Manuel du propriétaire - Page 10
Parcourez en ligne ou téléchargez le pdf Manuel du propriétaire pour {nom_de_la_catégorie} Aquasana AQ-SFRO. Aquasana AQ-SFRO 13 pages. Under sink water filter smartflow reverse osmosis
16
PERFORMANCE & CERTIFICATIONS
2
Model
Replacements
AQ-SFRO-S1S3
AQ-SFRO
AQ-SFRO-S2
AQ-SFRO-REMIN
Operating Temp. Range
Efficiency Rating
40-100° F
27.4%
4-37° C
Manufactured by: Aquasana, Inc.
4343 Hamilton Road · Groveport, OH 43125
System tested and certified by WQA to NSF/ANSI Standards 42, 53, 58, 401, and CSA B483.1 for
the reduction of the claims specified on the Performance Data Sheet and at
www.WQA.org. This system conforms to NSF/ANSI 53 for VOC reduction. See Performance
Data Sheet for individual contaminants and reduction performance. All claims are verified and
subastantiated by test data.
For systems that do not include a dedicated faucet:
In order to maintain the NSF/ANSI 58 certification of this product, the drain line installation must comply with the
standard requirements of a vertical air gap of two pipe diameters or 25 mm (1 in), whichever is larger, or an air gap
faucet that is tested and certified against NSF/ANSI 58 must be included.
For the full list of contaminants filtered, scan to view the
AQ-SFRO Performance Data Sheet on Aquasana.com.
Recovery Rating
42.8%
Daily Production
25.7 gpd
866-662-6885
Issue
Resolution
Water Leak/
Step 1:
Turn off the cold water valve underneath the sink
Drip
and depressurize the system by opening the faucet and
releasing all the water.
Step 2:
Ensure color-coded tubing is installed into the correct
placement on the system.
Step 3:
If cutting the tubing due to excess length, cut the
tubing straight across, not at an angle.
Correct
Step 4:
Check and make sure
the tubing is fully inserted into
the system manifold until tubing
can no longer be pushed. A
loose connection can cause a
leak at the inlet/outlet.
Step 5:
Once all tubing is installed, and the system is re-
connected, turn the water valve back on and check for leaks.
Step 6:
Make sure that the cartridges are in the locked
position. They should be rotated fully clockwise until the
handles are horizontal (see illustration on page 14).
NOTE: If the unit is still leaking after checking the
cartridges and tube connections, shut off the cold water
supply valve to the RO unit and contact Customer Support
at 866-662-6885.
Slow Flow
Step 1: Ensure water is flowing from the faucet. If water is
flowing, close faucet and come back in one hour to re-check
pressure. This will allow enough time for the tank to be filled.
Step 2: If it has been over six months since changing the
filter, advise replacement of filters.
TROUBLESHOOTING GUIDE
17
Incorrect
0.625"
Depth to insert tubing
(actual size)