Aquasana AQ-UV-C Series Instructions d'utilisation et d'installation - Page 9
Parcourez en ligne ou téléchargez le pdf Instructions d'utilisation et d'installation pour {nom_de_la_catégorie} Aquasana AQ-UV-C Series. Aquasana AQ-UV-C Series 16 pages.
Figure 5
High Output UV Lamp Connection
Step 11: Plug the lamp connector into the lamp. Note the keying for proper
alignment (see Figure 5). Insert the lamp connector into the gland nut and turn the
connector approximately ¼ turn to lock the connector to the gland nut as in Figure
6.
Figure 6
Lamp Connector
Figure 7
Ground Screw Connection
Step 12: Tighten the captive ground screw to the ground lug on the UV reactor to
ensure proper grounding as shown in Figure 7.
Step 13: Your system is now ready to be plugged into the appropriate GFCI
protected outlet. Refer to the following System Disinfection section before any water
is allowed to flow through the system.
System Disinfection
With a new installation, or any time the UV system is shut down for service, without
power, or is inoperative for any other reason, the lines in the home or facility could
be contaminated. Use the following steps to fully disinfect the lines throughout the
entire home or facility.
Step 1: Check for and remove any "dead ends" in the lines throughout the home
as these can harbor bacteria. Plug in the UV system and wait until it is ready for
operation.
Step 2: Remove the filter cartridge from the last sump and fill it with 1-2 cups of
household bleach (most are 5.25% chlorine). Replace the sump and slowly turn on
the water supply.
9