HP 316095-B21 - StorageWorks Edge Switch 2/24 Note de mise à jour - Page 6

Parcourez en ligne ou téléchargez le pdf Note de mise à jour pour {nom_de_la_catégorie} HP 316095-B21 - StorageWorks Edge Switch 2/24. HP 316095-B21 - StorageWorks Edge Switch 2/24 23 pages. Edge switch release notes
Également pour HP 316095-B21 - StorageWorks Edge Switch 2/24 : Manuel de mise à jour (9 pages), Manuel (41 pages), Manuel (40 pages), Note de mise à jour (32 pages), Note de mise à jour (27 pages), Manuel (26 pages), Note de mise à jour (27 pages), Note de mise à jour (25 pages), Manuel d'instructions d'installation (24 pages), Note de mise à jour (23 pages), Note de mise à jour (23 pages), Note de mise à jour (22 pages), Note de mise à jour (19 pages), Note de mise à jour (19 pages), Note de mise à jour (18 pages), Manuel d'instructions (17 pages), Note de mise à jour (17 pages), Instructions de mise à niveau (16 pages), Manuel d'instructions (16 pages), Manuel d'instructions d'installation (16 pages), Note de mise à jour (16 pages), Note de mise à jour (17 pages), Note de mise à jour (17 pages), Note de mise à jour (11 pages)

HP 316095-B21 - StorageWorks Edge Switch 2/24 Note de mise à jour
Fixes
Table 2
lists issues that have been fixed in this release since the release of firmware version 09.08.01.
Table
3lists issues that have been fixed in this release since the release of firmware version 09.07.02.
Table 2 Fixes in this release
Description
Zone activation could fail for fabrics with a large number
of zones.
Table 3 Fixes since firmware release 09.07.02
Description
Query Security Attributes (QSA) Registered Fabric Change
Notification (RFCN) is not sent to the registrants when the
state of insistent Domain ID is changed.
In firmware 09.07.xx, the port WWN does not change
along with the FC address when a port swap is executed.
The functionality of the port swap action is not impacted
by this.
Switch Binding restriction does not apply when Switch
Binding Membership List (SBML) has maximum allowed
entries.
When a Director 2/140 encountered a QPM 0, port 3
failure while disabled, the QPM indicated a failure in
"productinfo", but no event was posted.
Unable to config ports as E_ports with NPIV disabled.
When API authentication was enabled, EFCM erroneously
issued "too many sessions" error and did not manage
switch.
SS_FAULT (00000073) occurred on core Director 2/140
when ISLs were disconnected on a Director 2/64.
The Access Control List (ACL) list was not restored properly
when restoring modified configuration file.
Tunneling configurations were neither saved nor restored.
After an IML, an Edge Switch 2/24 incorrectly reported
port type for unavailable E_Port as "F-port unavailable".
Threshold Alerts were posted at invalid time stamp before
the stipulated time.
Logout to NPIV port did not reset registration, allowing
RLIR (Registered Link-Incident Report) to be presented.
C0 fault occurred on snmpwalk /get for SNMP v3 users
using Secure Hash Algorithm (SHA) protocol
6
Affected models
All
Affected models
All
All
All
Director 2/140
All
Director 2/140
Director 2/140
All
All
Edge Switch 2/24
All
All
All