Également pour HP 316095-B21 - StorageWorks Edge Switch 2/24 : Manuel de mise à jour (9 pages), Manuel (41 pages), Manuel (40 pages), Note de mise à jour (32 pages), Note de mise à jour (27 pages), Manuel (26 pages), Note de mise à jour (27 pages), Note de mise à jour (25 pages), Manuel d'instructions d'installation (24 pages), Note de mise à jour (23 pages), Note de mise à jour (23 pages), Note de mise à jour (22 pages), Note de mise à jour (23 pages), Note de mise à jour (19 pages), Note de mise à jour (18 pages), Manuel d'instructions (17 pages), Note de mise à jour (17 pages), Instructions de mise à niveau (16 pages), Manuel d'instructions (16 pages), Manuel d'instructions d'installation (16 pages), Note de mise à jour (16 pages), Note de mise à jour (17 pages), Note de mise à jour (17 pages), Note de mise à jour (11 pages)

HP 316095-B21 - StorageWorks Edge Switch 2/24 Note de mise à jour

Known Issues

Known Issues
This section describes the known issues related to the Edge Switch 2/24 and Edge
Switch 2/32.

Embedded Web Server access to modify zones is limited to first 255

zones
If you have an active zone set of greater than 255 zones, you will not be able to
access the zones past the 255th zone using the Embedded Web Server (EWS). The
higher number zone names are listed, but when accessed to modify the zone (for
example, the zone that would be numbered "n"), you will get the zone member list
for the (n-255) zone. This will be corrected in a future firmware release.
Workaround
Using the HAFM server to manage directors and edge switches will allow you to
modify zones in zone sets with greater than 255 zones.

SNMP trap reports incorrect FRU position

When an SNMP trap is sent and reports a FRU position number, the reported
number is one greater than the actual FRU position that caused the SNMP trap to
be issued.
Workaround
None.
Some IP Addresses must be Avoided
When you select IP addresses for edge switches and directors, and also if you
select a static IP address for the HAFM server, do not use IP addresses in the
following range:
16
192.168.0.0 through 192.168.0.255—This subnet is used internally to the
HAFM server. Using an IP address in this range causes the call-home feature
to function incorrectly.
Edge Switch Release Notes