HP StorageWorks 7110 - Virtual Array Manuel - Page 2

Parcourez en ligne ou téléchargez le pdf Manuel pour {nom_de_la_catégorie} HP StorageWorks 7110 - Virtual Array. HP StorageWorks 7110 - Virtual Array 4 pages. Private loop (hubs/direct connect)
Également pour HP StorageWorks 7110 - Virtual Array : Utilisation du manuel (34 pages), Instructions de mise à niveau (12 pages), Instructions (4 pages), Manuel (4 pages), Instructions d'installation (2 pages), Manuel (2 pages), Manuel (1 pages), Manuel (1 pages)

HP StorageWorks 7110 - Virtual Array Manuel
cfg
cfg -L <LUN ID> -a <capacity> [{G|g}|{K|k}] –g <RG Id>
cfg -L <LUN ID> -d
To Create a LUN requires three
parameters, LUN ID, capacity and RD
Id.
-L <LUN ID>: specify LUN ID to be
created.
-a <capacity>: specify LUN capacity.
Capacity is default to MB.
If followed by 'K' or 'k', the capacity is in
kilobytes and must be a multiple of
512.
If followed by 'G' or 'g', the capacity is in
gigabytes.
-g <RG ID>: redundancy group id. For
VA 7100 set to 1, for VA 7400 set to 1
or 2.
For valid number of LUNs to create,
check dsp –s for CREATE LUN LIMIT.
-L followed by –d: deletes LUN, no
need to specify capacity, just LUN ID.