When an HP StorageWorks DC SAN Backbone Director blade is
powered off, Fabric Watch displays unnecessary warning message
about SFP voltages.
The EnumerateSelectedInstances CAL call returns a port that
is not present in GFABRIC MS call.
FICON Tape Write Pipelining does not function with converter.
In configure tab under switch admin tab, if value entered in R_A_TOV
and E_D_TOV is more than the threshold, the error message displays
the wrong range of values to be entered.
Integrated Routing with multiple ports in an EX_Port trunk, may not
properly send an entire exchange on the same link.
Sort does not work on Accessible Devices screen of name server.
Seccertutil gencsr is not accepted in non-interactive mode if
parameter has a space in it.
IPAD FFDC error occurred after reboot of HP StorageWorks 4/8 or
4/16 SAN Switch.
HP StorageWorks 8/80 SAN Switch licenses disappeared and user
is not able to re-install them.
Switch Throughput Utilization Graph launches with all ports in graph
if we try launching by removing all ports from the edit Switch
Throughput Utilization dialog.
CUP Asynchronous Error Reporting Location not being set by default.
AG N_Port connected to embedded switch in interopmode 2 could
not restart traffic after switchdisable/enable followed by con-
figupload/download.
All ports come up Disabled (Persistent) after FMS mode is set while
switch is offline.
Fast Write could obtain incorrect FCP command data length if the
optional additional CDB length is selected.
Security Violation Console Message reported on un-existing port# on
an HP StorageWorks 4/64 SAN Switch (interopmode 2) with no se-
curity policy set.
Fabric OS does not send RSCN for CUP disable / enable in NI
mode 2.
36
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Ignore messages; they indicate no
problem and have no side effect.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Disable trunking on HP StorageWorks
DC SAN Backbone Director and HP
StorageWorks 8/8, 8/24, 8/40,
and 8/80 SAN switches EX_Ports.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Use the interactive mode to generate
the csr file.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Clean install.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.