Fastwrite will attempt to configure, even on an HP StorageWorks B-
Series Multi-protocol Router blade that has failed to initialize success-
fully.
Zoned crashes after HP StorageWorks DC SAN Backbone Director
power cycle and zone transaction aborted
SMIA does not have information about SFP/GBIC type for a port.
The tag field of the node identifier command returned contains the port
number on which the command was received, instead of the tag field
of the device on the other end of the link.
Gzoneinfo.htm is returning empty zone information on fabric with
Fabric OS 6.1.1.
Kernel Panic on 8Gb SAN Switch for HP BladeSystem c-Class after
firmwaredownload.
Conversion of uwatt to dbm for GE ports Tx Rx values shown in Web
Tools are incorrect.
HP StorageWorks 8/40 SAN Switch: FRU faulty status is not recovered
correctly.
Third-party array responds to ADISC with LOGO only over router
fabric, S_ID does not match N_ID.
Ipfilter – Audit log (SEC- 3035, 3036, 3037): message properties
generating log without the appropriate key word.
AG trunks are not formed correctly when connected to an embedded
switch.
Tape Selective Reset error due to incorrect handling of Early End Syn-
chronization status.
F_port prefers to multiple N_ports
FICON Device Level Ack Emulation Processing error.
38
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
The embedded platforms have well
known user/server ports documented
in the user manuals.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Reboot the switch.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Turn on the power switch as soon as
possible after inserting a fan/power
supply unit into the system.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
For McDATA mode edge fabric, only
McDATA switches have to be connec-
ted directly to FCR. The work around
is valid as long as we have only
McDATA switches directly connected
to Ex-Ports.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.