HP StorageWorks XP10000 - Disk Array Manuel de l'utilisateur - Page 21

Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} HP StorageWorks XP10000 - Disk Array. HP StorageWorks XP10000 - Disk Array 30 pages. Cache lun xp
Également pour HP StorageWorks XP10000 - Disk Array : Note de mise à jour (13 pages), Manuel de l'administrateur (50 pages), Manuel de configuration (42 pages), Manuel de configuration (40 pages), Manuel de configuration (40 pages), Manuel de configuration (36 pages), Manuel de configuration (36 pages), Manuel de configuration (30 pages), Manuel de configuration (36 pages), Note de mise à jour (5 pages), Manuel de configuration du système (49 pages), Manuel de configuration du système (43 pages), Manuel de configuration du système (42 pages), Manuel de configuration du système (35 pages), Manuel de configuration (46 pages), Manuel de configuration (46 pages), Manuel de configuration (40 pages), Manuel de configuration (44 pages), Manuel de configuration (38 pages), Manuel de configuration (34 pages), Manuel de configuration (30 pages), Manuel de configuration (30 pages), Manuel de configuration (42 pages)

HP StorageWorks XP10000 - Disk Array Manuel de l'utilisateur
c. Click OK to continue. The Multi Release window appears.
Figure 5

Multi Release window

d. In the CU box, click the CU.
e. In the table, click more than one LDEV and then click Release. The Multi Release pane closes and
the new settings are shown in blue on the Cache LUN pane. To cancel operations, click Cancel. Go
to
step
6.
To remove cache data for another CU:LDEV, repeat the previous steps.
7.
If the deletions are correct, click Apply. A confirmation dialog box appears.
8.
Click OK to confirm. The Cache LUN XP operation begins. If prestaging was selected, the prestaging
operation will occur next. When the operation has been completed, a confirmation dialog box
appears.
9.
Click OK.
NOTE:
Response time might be slow if you try to delete cache-resident data. This causes a conflict
because host I/O occurs at the same time data is written to the disk drive (destaging). To avoid slow
response time, limit the amount of data you try to delete during one operation as follows:
When the host timeout period is set to 11 seconds or more
Open system: 3 GB or less
Mainframe system: 3,000 cylinders or less
When the host timeout period is set to 10 seconds or less
Open system: 1 GB or less
Mainframe system: 1,000 cylinders or less

Changing an extent's mode and pre-staging

You cannot directly change a cache extent's mode or pre-staging settings. You must delete the extent and
reconfigure it with new settings.
1.
Select and release (remove) the extent in the Cache LUN XP cache.
2.
Remake the extent with the new mode and pre-staging settings.
6.
Cache LUN XP user guide for the XP10000/XP12000
21