Alpha Group Out Back Power MATE Series Vue d'ensemble - Page 9
Parcourez en ligne ou téléchargez le pdf Vue d'ensemble pour {nom_de_la_catégorie} Alpha Group Out Back Power MATE Series. Alpha Group Out Back Power MATE Series 14 pages. System display and controller
Advanced Inverter Setup Menu
Page 1
Continued from
ADV/FX/PAGE1
choose category
previous page....
ADV
INV
CHRG
PG2
Page 2
ADV/FX/PAGE2--------P01
choose category
ADV GRID
GEN
PG3
ADV/FX/GRID---------P01
ADV/FX/GEN----------P01
ac 1/grid
108
gen input
00.5 min
Vac lower limit
connect delay
DOWN
INC
DEC
PORT
DOWN
INC
DEC
ADV/FX/GRID---------P01
ADV/FX/GEN----------P01
ac 1/grid
140 Vac
ac 2/gen
upper limit
lower limit
DOWN
INC
DEC
PORT
DOWN
INC
DEC
ADV/FX/GRID---------P01
ADV/FX/GEN----------P01
ac 1/grid
48.0 Aac
ac 2/gen
140.0 Aac
input limit
upper limit
DOWN
INC
DEC
PORT
DOWN
INC
DEC
ADV/FX/GRID---------P01
ADV/FX/GEN----------P01
ac 1/grid
6 cycles
ac 2/gen
48.0 Aac
transfer delay
input limit
DOWN
INC
DEC
PORT
DOWN
INC
DEC
ADV/FX/GRID---------P01
ADV/FX/GEN----------P01
grid programming
ac 2/gen
completed
cycles transfer delay
TOP
ADV
MAIN
DOWN
INC
DEC
ADV/FX/GEN----------P01
ac 2/gen
support
DOWN
INC
DEC
ADV/FX/GEN----------P01
gen programming
completed
TOP
ADV
900-0131-01-00 Rev A.vsd\INV Setup 2\2012-03-21
©2012 OutBack Power Technologies. All Rights Reserved.
(continued)
(continued)
ADV/FX/AUX-----------P01
aux output
AUTO
control
DOWN
INC
DEC
PORT
ADV/FX/AUX-----------P01
aux output
cool fan
function
PORT
DOWN
INC
DEC
PORT
ADV/FX/AUX-----------P01
108 Vac
genalert
22.0 Vdc
on setpoint
PORT
DOWN
INC
DEC
PORT
ADV/FX/AUX-----------P01
genalert
4 min
on delay
PORT
DOWN
INC
DEC
PORT
ADV/FX/AUX-----------P01
genalert
28.0 Vdc
off set point
PORT
DOWN
INC
DEC
PORT
ADV/FX/AUX-----------P01
60
genalert
9 min
off delay
PORT
DOWN
INC
DEC
PORT
ADV/FX/AUX-----------P01
ON
loadshed
22.0 Vdc
off set point
PORT
DOWN
INC
DEC
PORT
ADV/FX/AUX-----------P01
vent fan
26.0 Vdc
on set point
MAIN
DOWN
INC
DEC
PORT
Page 3
ADV/FX/PAGE3---------P01
choose category
PG2
AUX STACK
PG4
ADV/FX/STACK---------P01
stack 1-2PH Master
phase
DOWN
INC
DEC
PORT
ADV/FX/STACK---------P01
stack Classic Slave
phase
DOWN
INC
DEC
PORT
ADV/FX/STACK---------P01
stack OB Slave L1
phase
DOWN
INC
DEC
PORT
ADV/FX/STACK---------P01
stack OB Slave L2
phase
DOWN
INC
DEC
PORT
ADV/FX/STACK---------P01
ADV/FX/AUX-----------P01
stack 3PH Master
vent fan off
5 min
phase
period
DOWN
INC
DEC
PORT
DOWN
INC
DEC
PORT
ADV/FX/STACK---------P01
ADV/FX/AUX-----------P01
stack 3 PH Slave
diversion
29.2 Vdc
phase
on set point
DOWN
INC
DEC
PORT
DOWN
INC
DEC
PORT
ADV/FX/STACK---------P01
ADV/FX/AUX-----------P01
power save level 0
diversion
30 sec
master adjust only
off delay
DOWN
INC
DEC
PORT
DOWN
INC
DEC
PORT
ADV/FX/AUX-----------P01
aux output
setup completed
TOP
ADV
MAIN
To return to the Main
screen at any time:
Press and hold the 2 left soft keys at the same
time. Release when the Main screen appears.
NOTE: The values shown in this illustration
will vary depending on the model of inverter.
Page 4
ADV/FX/PAGE4---------P01
choose category
PG3 SELL
ADV/FX/SELL----------P01
sell re 23.6 Vdc
volts
DOWN
INC
DEC
ADV/FX/SELL----------P01
grid tie IEEE
window
DOWN
IEEE
USER
ADV/FX/SELL----------P01
ADV/FX/STACK---------P01
power save level 0
grid tie
GRIDTIE
authority
slave adjust only
DOWN
INC
DEC
PORT
DOWN
IEEE
USER
ADV/FX/STACK---------P01
ADV/FX/SELL----------P01
stacking
selling
setup completed
setup completed
TOP
ADV
MAIN
TOP
ADV
MAIN--------------------
SUM STATUS SETUP
MAIN-------------------
3:02:14P
SUM STATUS
SETUP ADV
CAL
MAIN
ADV/FX/CALIBRATE-----P01
Vac input 120 vac
adjustment
DOWN
INC
DEC
PORT
PORT
ADV/FX/CALIBRATE-----P01
Vac output 120 Vac
adjustment
PORT
DOWN
INC
DEC
PORT
ADV/FX/CALIBRATE-----P01
battery Vdc 25.4 Vdc
adjustment
DOWN
INC
DEC
PORT
PORT
ADV/FX/CALIBRATE-----P01
calibration
setup completed
MAIN
TOP
ADV
MAIN
3:02:14P
ADV
Page 7