Alpha Group Out Back Power MATE Series Ikhtisar - Halaman 9
Jelajahi secara online atau unduh pdf Ikhtisar untuk Unit Kontrol Alpha Group Out Back Power MATE Series. Alpha Group Out Back Power MATE Series 14 halaman. System display and controller
Advanced Inverter Setup Menu
Page 1
Continued from
ADV/FX/PAGE1
choose category
previous page....
ADV
INV
CHRG
PG2
Page 2
ADV/FX/PAGE2--------P01
choose category
ADV GRID
GEN
PG3
ADV/FX/GRID---------P01
ADV/FX/GEN----------P01
ac 1/grid
108
gen input
00.5 min
Vac lower limit
connect delay
DOWN
INC
DEC
PORT
DOWN
INC
DEC
ADV/FX/GRID---------P01
ADV/FX/GEN----------P01
ac 1/grid
140 Vac
ac 2/gen
upper limit
lower limit
DOWN
INC
DEC
PORT
DOWN
INC
DEC
ADV/FX/GRID---------P01
ADV/FX/GEN----------P01
ac 1/grid
48.0 Aac
ac 2/gen
140.0 Aac
input limit
upper limit
DOWN
INC
DEC
PORT
DOWN
INC
DEC
ADV/FX/GRID---------P01
ADV/FX/GEN----------P01
ac 1/grid
6 cycles
ac 2/gen
48.0 Aac
transfer delay
input limit
DOWN
INC
DEC
PORT
DOWN
INC
DEC
ADV/FX/GRID---------P01
ADV/FX/GEN----------P01
grid programming
ac 2/gen
completed
cycles transfer delay
TOP
ADV
MAIN
DOWN
INC
DEC
ADV/FX/GEN----------P01
ac 2/gen
support
DOWN
INC
DEC
ADV/FX/GEN----------P01
gen programming
completed
TOP
ADV
900-0131-01-00 Rev A.vsd\INV Setup 2\2012-03-21
©2012 OutBack Power Technologies. All Rights Reserved.
(continued)
(continued)
ADV/FX/AUX-----------P01
aux output
AUTO
control
DOWN
INC
DEC
PORT
ADV/FX/AUX-----------P01
aux output
cool fan
function
PORT
DOWN
INC
DEC
PORT
ADV/FX/AUX-----------P01
108 Vac
genalert
22.0 Vdc
on setpoint
PORT
DOWN
INC
DEC
PORT
ADV/FX/AUX-----------P01
genalert
4 min
on delay
PORT
DOWN
INC
DEC
PORT
ADV/FX/AUX-----------P01
genalert
28.0 Vdc
off set point
PORT
DOWN
INC
DEC
PORT
ADV/FX/AUX-----------P01
60
genalert
9 min
off delay
PORT
DOWN
INC
DEC
PORT
ADV/FX/AUX-----------P01
ON
loadshed
22.0 Vdc
off set point
PORT
DOWN
INC
DEC
PORT
ADV/FX/AUX-----------P01
vent fan
26.0 Vdc
on set point
MAIN
DOWN
INC
DEC
PORT
Page 3
ADV/FX/PAGE3---------P01
choose category
PG2
AUX STACK
PG4
ADV/FX/STACK---------P01
stack 1-2PH Master
phase
DOWN
INC
DEC
PORT
ADV/FX/STACK---------P01
stack Classic Slave
phase
DOWN
INC
DEC
PORT
ADV/FX/STACK---------P01
stack OB Slave L1
phase
DOWN
INC
DEC
PORT
ADV/FX/STACK---------P01
stack OB Slave L2
phase
DOWN
INC
DEC
PORT
ADV/FX/STACK---------P01
ADV/FX/AUX-----------P01
stack 3PH Master
vent fan off
5 min
phase
period
DOWN
INC
DEC
PORT
DOWN
INC
DEC
PORT
ADV/FX/STACK---------P01
ADV/FX/AUX-----------P01
stack 3 PH Slave
diversion
29.2 Vdc
phase
on set point
DOWN
INC
DEC
PORT
DOWN
INC
DEC
PORT
ADV/FX/STACK---------P01
ADV/FX/AUX-----------P01
power save level 0
diversion
30 sec
master adjust only
off delay
DOWN
INC
DEC
PORT
DOWN
INC
DEC
PORT
ADV/FX/AUX-----------P01
aux output
setup completed
TOP
ADV
MAIN
To return to the Main
screen at any time:
Press and hold the 2 left soft keys at the same
time. Release when the Main screen appears.
NOTE: The values shown in this illustration
will vary depending on the model of inverter.
Page 4
ADV/FX/PAGE4---------P01
choose category
PG3 SELL
ADV/FX/SELL----------P01
sell re 23.6 Vdc
volts
DOWN
INC
DEC
ADV/FX/SELL----------P01
grid tie IEEE
window
DOWN
IEEE
USER
ADV/FX/SELL----------P01
ADV/FX/STACK---------P01
power save level 0
grid tie
GRIDTIE
authority
slave adjust only
DOWN
INC
DEC
PORT
DOWN
IEEE
USER
ADV/FX/STACK---------P01
ADV/FX/SELL----------P01
stacking
selling
setup completed
setup completed
TOP
ADV
MAIN
TOP
ADV
MAIN--------------------
SUM STATUS SETUP
MAIN-------------------
3:02:14P
SUM STATUS
SETUP ADV
CAL
MAIN
ADV/FX/CALIBRATE-----P01
Vac input 120 vac
adjustment
DOWN
INC
DEC
PORT
PORT
ADV/FX/CALIBRATE-----P01
Vac output 120 Vac
adjustment
PORT
DOWN
INC
DEC
PORT
ADV/FX/CALIBRATE-----P01
battery Vdc 25.4 Vdc
adjustment
DOWN
INC
DEC
PORT
PORT
ADV/FX/CALIBRATE-----P01
calibration
setup completed
MAIN
TOP
ADV
MAIN
3:02:14P
ADV
Page 7