3.4

MOUNTING WITH CLAMPS

It is the installer's responsibility to ensure that the clamps used to attach the module are strong enough.
Figure 4 shows the module mounted with clamp.
Module
frame
Clamp
The clamps must not be in contact with the front glass or deform the frame in any way. Avoid shading
effects from the clamps and mounting system.
3.5

GROUNDING

All module frames and mounting racks must be properly grounded in accordance with the appropriate
respective National Electrical Code.
Proper grounding is achieved by bounding the module frame and all metallic structural members
together continuously using a suitable grounding conductor. The grounding conductor or strap may be
copper, copper alloy or other material acceptable for use as an electrical conductor per respective
National Electrical Codes. The grounding conductor must make a connection to earth using a suitable
earth ground electrode.
4

ELECTRICAL INSTALLATION

4.1

GENERAL WIRING

All wiring should be done in accordance with applicable local electrical codes.