6.2 Setting the operating mode
The AXIbox has two operating modes. The changeover may only be carried out by a specialist, taking into
account all necessary safety precautions.
6.2.1 Control via RFID
When delivered, the AXIbox is protected against unauthorised use by a lock. The charging process is started
by the RFID cards supplied. If this operating mode is desired, no changes need to be made.
In order to use the RFID cards to activate the charging process, the jumper marked in the above image must
be in the position shown. If the AXIbox was previously in Plug & Play mode, the jumper must be moved
back to the position shown above to switch to RFID mode.
6.2.2 Plug & Play
In Plug & Play mode, charging can be started after inserting the charging plug into the car's charging socket
without further activation. To switch to this mode, the jumper marked in the image below must be placed
in the position shown.
EN211103