Parcourez en ligne ou téléchargez le pdf Livre blanc pour {nom_de_la_catégorie} Cisco 6500 - Catalyst Series 10 Gigabit EN Interface Module Expansion. Cisco 6500 - Catalyst Series 10 Gigabit EN Interface Module Expansion 19 pages. Distributed forwarding card 4 for ws-x68xx, ws-x69xx, and select ws-x67xx modules
Également pour Cisco 6500 - Catalyst Series 10 Gigabit EN Interface Module Expansion : Note d'installation (14 pages), Manuel de solution (17 pages), Note d'installation (46 pages), Description (1 pages), Bulletin d'information sur les produits (6 pages), Avis (4 pages), Fiche technique (9 pages), Fiche technique (18 pages), Livre blanc (18 pages), Manuel de configuration (8 pages), Note d'installation (28 pages), Manuel de dépannage (11 pages), Note d'installation (18 pages), Manuel de l'utilisateur (17 pages), Note d'installation (24 pages), Manuel (19 pages), Note d'installation (36 pages)

Cisco 6500 - Catalyst Series 10 Gigabit EN Interface Module Expansion Livre blanc
The changes to the switching mode are done automatically, depending on the hardware installed. No specific configuration is
necessary on the SFM for typical operation. The current switching mode of the switch fabric module can be monitored through
the Catalyst OS command-line interface (CLI) using the show fabric channel switchmode command. Example 1 shows a
completely fabric-enabled system (all compact mode) and Example 2 shows classic and fabric-enabled line cards in an SFM
system (flow-through and truncated mode).
Example 1: Fabric-Enabled System
The following output is from a configuration with dual supervisor engines, one SFM, and a fabric-enabled line card in slot 3.
Sup2-A> (enable) show fabric channel switchmode
Module Num Fab Chan Fab Chan Switch Mode
------ ------------ -------- ------------ --------------
1
1 0, 0 compact
2
1 0, 1 compact
3
1 0, 2 compact
5
18 0, 0 n/a
5
18 1, 1 n/a
5
18 2, 2 n/a
5
18 3, 3 n/a
5
18 4, 4 n/a
5
18 5, 5 n/a
5
18 6, 6 n/a
5
18 7, 7 n/a
5
18 8, 8 n/a
5
18 9, 9 n/a
5
18 10, 10 n/a
5
18 11, 11 n/a
5
18 12, 12 n/a
5
18 13, 13 n/a
5
18 14, 14 n/a
5
18 15, 15 n/a
5
18 16, 16 n/a
5
18 17, 17 n/a
15
0 n/a
n/a
16
0 n/a
n/a
CLI output description for show fabric channel switchmode:
Num Fab Chan—The number of fabric channels that the module is associated with.
Fab Chan—The first number is the fabric channel number that the module is associated with. The second number is the fabric
channel number that the SFM is associated with.
Switch mode—Possible output is "flow through," "truncated," "compact." Switch mode applies only to line cards with fabric
and bus connections.
Channel status—Possible output is "ok," "sync error," "CRC error," "heartbeat error," "buffer error," "timeout error," or
"unknown." Channel status applies only to line cards with fabric and bus connections.
All contents are Copyright © 1992–2002 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
Channel Status
ok
ok
ok
ok
ok
ok
unknown
unknown
unknown
unknown
unknown
unknown
unknown
unknown
unknown
unknown
unknown
unknown
unknown
unknown
unknown
n/a
n/a
Cisco Systems, Inc.
Page 3 of 19