Également pour Cisco 9124 - mds multilayer fabric switch : Spécifications (2 pages), Fiche technique (9 pages), Spécifications (3 pages), Manuel de configuration (49 pages), Note de mise à jour (48 pages), Note de mise à jour (44 pages), Note de mise à jour (36 pages), Note de mise à jour (22 pages), Note de mise à jour (3 pages), Note de mise à jour (40 pages), Manuel (16 pages)

Cisco 9124 - mds multilayer fabric switch Manuel d'installation du matériel
Installing the Switch in a Cabinet or Rack
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
The rack-mount kit provided with the switch contains the items listed in
Table 2-1
Description
30- to 36-inch slider rails
24- to 30-inch slider rails
18- to 24-inch slider rails
Front rack-mount brackets
12-24 x 3/4-inch Phillips binder-head screws
10-32 x 3/4-inch Phillips binder-head screws
M4 x 6-mm Phillips flat-head screws
12-24 Cage nuts
Front-Facing Installation
To install the switch in a cabinet or rack using the rack-mount kit provided with the switch, follow these
steps:
Install the front rack-mount bracket as follows:
Step 1
a.
b.
Install the C brackets as follows:
Step 2
Note
a.
b.
Cisco MDS 9100 Series Hardware Installation Guide
2-6
Cisco MDS 9148, MDS 9134, and Cisco MDS 9124 Fabric Switch Rack-Mount Kit
Position one of the front rack-mount brackets against the side of the switch and align the screw holes
as shown in
Figure
2-1. Then attach the bracket to the switch with the three M4 screws originally
provided with the bracket.
Repeat with the other front rack-mount bracket on the other side of the switch.
Two C brackets are shipped preinstalled on the switch, using three M3 screws per bracket. This
installation step is only necessary if the C brackets were removed.
Position one of the C brackets against the side of the switch and align the screw holes as shown in
Figure
2-1. Then attach the bracket to the switch with the three M3 screws originally provided with
the bracket.
Repeat with the other C bracket on the other side of the switch.
Chapter 2
Installing the Cisco MDS 9100 Series
Table
Quantity
2 per kit
2 per kit
2 per kit
2 per kit
10 per kit
10 per kit
6 per kit
10 per kit
2-1.
OL-21514-01