4.
Specifications
• Power Requirements:
Dual Supply, 5 ± 0.1 Volts DC Regulated; 2.4 Amperes maximum
Power Connector Type: Dual 2.0 mm Locking Mini Power Jack, Long Version (12.0 mm) –
L722A
• Power Supply:
Input: 100-120V AC, 47-63 Hz; 0.75 Amperes
Grounding: 3 prong outlet with true earth ground required. Earth ground should be connected to
DC ground return.
Power Connector Type: 2.0 mm Locking Mini Power Plug, Long Version (12.0 mm) – S761K
• Signal Timing:
Data rate: 38.4 kbps nominal, 500 kbps maximum
Maximum Propagation Delay (DE9 connector to DE9 connector): 1.3 microseconds
• Rear Interface:
Connector Type: DE9 Female
Life Cycle: 10,000 Insertions minimum
Electrical Interface Protocol: EIA RS-422-A
Differential Input Impedance (Receiver): 1,000 Ohms
Maximum Number of Standard (4,000 Ohms Input Impedance) RS422 Receivers per Driver
(assuming a 100 Ohm termination on one side of the bus): 52
Maximum RS422 Connection Distance (one-way, assuming 100 Ohm bus termination): 1220 m
(4003 ft.)
• Front Interface:
Connector Type: Bantam (TT) Audio Jacks
Life Cycle: 30,000 Insertions minimum
Patchcord: Standard Bantam (TT) Audio (3 conductor)
• Environmental:
Operating Temperature: 0ºC to 70ºC
Storage Temperature: –55ºC to 85ºC
Page 13 – Bittree RS-422 64-Port Active Data Patchbay User Guide