Siemens SIMATIC PCS 7 Manuel - Page 27
Parcourez en ligne ou téléchargez le pdf Manuel pour {nom_de_la_catégorie} Siemens SIMATIC PCS 7. Siemens SIMATIC PCS 7 39 pages. Process control system, basis library readme v9.0 sp1 online
Également pour Siemens SIMATIC PCS 7 : Manuel d'introduction (6 pages), Manuel du système (28 pages), Manuel des fonctions (42 pages), Manuel d'utilisation (36 pages), Lisez-moi (26 pages)
4 Parameterization
2. If selecting "Quick Startup", it is recommended to start from a factory reset.
If you have no done so already, select "Yes".
Figure 4-4
3. Configure the power supply and the motor data of the drive to suit your
connected motor (type, motor current, motor power, motor speed, motor
voltage, motor frequency).
Figure 4-5
A faulty configuration can cause damage to the motor.
CAUTION
4. Configure the minimum and maximum frequency as well as the ramp times of
the drive to suit your application.
Figure 4-6
Integration of a SINAMICS G120X frequency converter in PCS 7
Entry ID: 109793986,
V1.0,
09/2021
27