ActronAir WRE-072CS Manuel du propriétaire - Page 7
Parcourez en ligne ou téléchargez le pdf Manuel du propriétaire pour {nom_de_la_catégorie} ActronAir WRE-072CS. ActronAir WRE-072CS 16 pages. Wall hung systems
Également pour ActronAir WRE-072CS : Manuel d'installation et de configuration (16 pages)
Owner's Manual
Breeze Away
This feature stops direct air from blowing onto you.
Refrigerant Leakage Detection
The indoor unit will automatically display EL0C when it detects refrigerant leakage. Switch system off and contact
service or installer.
Intuitive Proximity Sensor
This feature detects the occupancy of the people in the room. When in COOL mode, if you are away for 30 minutes, the
unit will automatically lower the frequency of the unit to save energy. The unit will automatically resume operation after
sensing activity in the room.
LED Display
Press the LED button on the remote control to turn off the indoor unit panel display and cancel the 'beep' noise.
Freeze Protection
When the unit is on HEAT mode and indoor temperature drops below 8 °C - FP will be displayed and system will enter
freeze protection mode.
03.04. Setting Vertical Angle of Air Flow
While the unit is on, use the SWING button on the remote control to set the vertical angle airflow direction. Refer to
Remote Control manual for more details.
03.05. Setting Horizontal Angle of Air Flow
While the unit is on, press and hold the SWING button on the remote control to set the vertical angle airflow direction.
Refer to Remote Control manual for more details.
NOTE
• When using COOL or DRY mode, do not set vertical louvre to the minimum angle for long periods of time. This can
cause water to condense on the louvre blade, which may drop on your floor or furnishings.
• When using COOL or HEAT mode, setting the vertical louvre to the minimum angle can reduce the performance of
the unit due to restricted air flow.
• Do not move louvre by hand. This will cause the louvre to become out of sync. If this occurs, reset mains power supply
isolator to restart the unit. This will reset the louvre.
CAUTION
Do not put your fingers in or near the blower. The high-speed fan inside the unit may cause injury.
Wall Hung Split System
Owner's Manual - Wall Hung Split System
Doc. No.9590-4011 Ver. 2 210622
7