Actuator Systems TCR-40C Series Instructions d'utilisation - Page 2

Parcourez en ligne ou téléchargez le pdf Instructions d'utilisation pour {nom_de_la_catégorie} Actuator Systems TCR-40C Series. Actuator Systems TCR-40C Series 7 pages. Intelligent on/off actuator

TCR-40C-All
Series-Intelligent on/off actuator usage instructions

Technical data

Electrical data
Functional data
Working conditions
*1
Operating mode: The testing environment temperature is 25 ℃ inside the factory. The testing standard as per IEC 60034-1-2017.The operation mode will be S3-90% if fthe
loading less than 60% rated torque..
*2.(1) It is customized item when used and stored under special ambient temperature of -20℃~-40℃,and special instructions are required.
(2) At the ambient temperature of - 40 ℃, power on is required for more than 15 minutes (30 minutes is recommended) before use. The higher the ambient temperature is,
the shorter the power on time can be.
(3) If user use the product at the ambient temperature of -40℃ for long time, it needs to be insulated.For example,add heating cable around the actuator.If the ambient
temperature is over -20℃,then the heating cable can be canceled.
PART 2
2
User Manual
Rated voltage
Rated voltage range
Power consumption
Peak current
@Rated Voltage
Fuse
Connector
Rated torque
Angle of rotation
Max angle of rotation
Manual operation
Running time
Operating mode
Sound power level
Position indicator
Electricity safety level
Inflaming retarding level
Enclosure
Insulation resistance
Withstand voltage
Medium temperature
Working environment
Explosion-proof level
Ambient temp
Non-operation temp
Humidity
*2
Ambient temperature
Success comes from our persistent pursue of perfect details.
Excellence originates from our persistence of win-win philosophy.
AC/DC95-265V(50/60HZ)
AC95-265V/DC100-300V
80W@MAX22W@running 5.9W@holding
0.36A/5ms@AC230V
2A
7*0.5mm² cable, voltage withstand AC300V (Length 800mm)
9*0.5mm² cable, voltage withstand AC300V (Length 800mm)
10P-5.08-500V ×(0.5-1.5)mm2 terminal
400Nm@rated voltage
90±2°
330±5°
Matching hexagon wrench,using at no power
About 25s
S3-85%(loading ≤85% rated torque refer to IEC60034-1-2017 *1)
65dB(A)
Mechanical and screen
I Type (ground protection )
1.6mmHB/UL94 test method
IP67 As Per En60529/GB4208-2008 (all directions)
F type can add dehumidifying heater
100MΩ/500VDC
1500VAC@1Min
≤80°can install with actuator directly
※>80° need to install bracket or heat radiation stand
Indoor or outdoor; if exposed to the rain or sunshine,
need to install protective device for the actuator
Not explosion proof products, do not use in flammable
and explosive environment.
-15℃-+45℃(PC+PET)
≤-40℃ or ≥80℃
5-95%RH non-condensing
[1]Ambient temperature <5℃,additional HTR is recommended.
[2]Ambient temperature <5 ℃and humidity>60%,
HTR +desiccant is recommended.
[3]Ambient temperature<5℃and humidity>80%,
HTR+desiccant+three preventing painting is recommended
[4]Ambient temperature>5℃and humidity>60%,
additional three preventing painting is recommended.
[5]Ambient temperature>5℃and humidity>80%,
additional desiccant+three preventing painting is recommended.
ISO9001
AC/DC24V
AC20-26V/DC22-30V
80W@MAX;19.2W@running 2.4W@holding
3.30A@5ms@DC24V
8A
III Type (ground protection )
100MΩ/500VDC
500VAC@1Min
®
特克
.com
Made in china Global service