Cisco NCS 4000 Series Manuel de dépannage - Page 42

Parcourez en ligne ou téléchargez le pdf Manuel de dépannage pour {nom_de_la_catégorie} Cisco NCS 4000 Series. Cisco NCS 4000 Series 44 pages. Network convergence system
Également pour Cisco NCS 4000 Series : Manuel de déballage, de déménagement et de sécurisation (40 pages)

Cisco NCS 4000 Series Manuel de dépannage
TIMING-PLL-VAL-ERROR
If the condition does not clear, log into the Technical Support Website at
index.html
TIMING-PLL-VAL-ERROR
Default Severity: Critical.
Logical Object: None
TIMING-PLL-VAL-ERROR alarm occurs when the Timing-PLL version check has failed.
Clear the TIMING-PLL-VAL-ERROR Alarm
Procedure
Step 1
Verify FPD status for Timing-FPGA and ECU-FPGA, use the show hw-module fpd <fpd-name> command.
Step 2
If the FPD(s) status is not CURRENT, then upgrade to the running version using upgrade hw-module
location all fpd <fpd-name> command.
Step 3
Reload the LC using hw-module location <LC location> reload command.
Note
Note
If the condition does not clear, log into the Technical Support Website at
index.html
Alarms Troubleshooting Guide for Cisco NCS 4000 Series
28
for more information or call Cisco TAC (1 800 553-2447).
Perform LC reload only if reload is required to complete the FPD upgrade.
Reload is traffic impacting operation and should be carried in planned maintenance window.
for more information or call Cisco TAC (1 800 553-2447).
Alarm Management
http://www.cisco.com/c/en/us/support/
http://www.cisco.com/c/en/us/support/