TIMING-PLL-VAL-ERROR
If the condition does not clear, log into the Technical Support Website at
index.html
TIMING-PLL-VAL-ERROR
Default Severity: Critical.
Logical Object: None
TIMING-PLL-VAL-ERROR alarm occurs when the Timing-PLL version check has failed.
Clear the TIMING-PLL-VAL-ERROR Alarm
Procedure
Step 1
Verify FPD status for Timing-FPGA and ECU-FPGA, use the show hw-module fpd <fpd-name> command.
Step 2
If the FPD(s) status is not CURRENT, then upgrade to the running version using upgrade hw-module
location all fpd <fpd-name> command.
Step 3
Reload the LC using hw-module location <LC location> reload command.