CAB HS 120 Manuel de l'opérateur - Page 13
Parcourez en ligne ou téléchargez le pdf Manuel de l'opérateur pour {nom_de_la_catégorie} CAB HS 120. CAB HS 120 18 pages. Label dispenser
4
Operation
4.1.2 Error Treatment
If no label is detected by the present sensor within 5 seconds after starting
the peel-off operation, the label transport will be stopped and an error will be
signalized :
The red LED (1) is flashing.
•
Cause
Out of labels
The peeled label does not activate
the present sensor
Table 2
Fault Correction
Rectify error.
Continue operation by releasing the present sensor manually.
Remedy
Insert new material
Adjust present sensor
13