- ページ 13

ラベルメーカー CAB HS 120のPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。CAB HS 120 18 ページ。 Label dispenser

4
Operation

4.1.2 Error Treatment

If no label is detected by the present sensor within 5 seconds after starting
the peel-off operation, the label transport will be stopped and an error will be
signalized :
The red LED (1) is flashing.
Cause
Out of labels
The peeled label does not activate
the present sensor
Table 2
Fault Correction
 Rectify error.
 Continue operation by releasing the present sensor manually.
Remedy
Insert new material
Adjust present sensor
13