Argo ULISSE ECO Manuel d'utilisation - Page 14

Parcourez en ligne ou téléchargez le pdf Manuel d'utilisation pour {nom_de_la_catégorie} Argo ULISSE ECO. Argo ULISSE ECO 16 pages. Room air conditioner with remote condenser
Également pour Argo ULISSE ECO : Manuel d'installation (14 pages)

Argo ULISSE ECO Manuel d'utilisation

TIPS FOR ENERGY SAVING

EN
DO NOT:
Block the air intake and outlet of the unit.
If they are obstructed, the unit will not work well, and
may be damaged.
Let direct sunlight into the room. Use sunshades, blind
or curtain.
DO:
Always try to keep the air filter clean. A clogged filter
will impair the performance of the unit.
To prevent conditioned air from escaping, keep
windows, doors and any other openings closed.

TROUBLESHOOTING

The use of portable telephones near the air-conditioner
may cause disturbance to its normal operation and
must be avoided. In case abnormal operation is noticed,
(OPERATION lamp lights but outdoor unit will not run)
to restore normal operation turn-off electric supply for
60 seconds at least, by disconnecting the main switch
or the wall plug, then start again the air-conditioner.
The blinking OPERATION lamp, together with the stop
of the air conditioner for a short time are due to the
exceeding condensate drainage. (see table "AUTO-
DIAGNOSIS")
If the OPERATION lamp goes on blinking and the air
conditioner definitely stops means that the condensate
pump is not working or that the condensate drain pipe
in the flexible connection pipe is obstructed; in this case
contact the AFTER SALE SERVICE.
In case of emergency the air conditioner can work by
draining the condensate from the back little pipe into a
rather short container: extract the little pipe and remove
the cap.
If your air conditioner does not work properly, first check
the following points before requesting service.
If it still does not work properly, contact your dealer or
service center.
AUTO-DIAGNOSIS
N.
TIMER
-
E1
E2
O
E3
E4
E5
E6
O
E7
O
E8
E9
O
O = LED off
LED
OPERATION
STANDBY
Heating mode not available
Communication error with HMI receiver PCB (WiFi model only)
O
Condensate drainage error (fl oat error)
PFC error (over current, over voltage or PFC communication error) Contact service centre
O
Internal fan malfunction
O
Inverter PCB overtemperature (compressor module)
Compressor overcurrent
Defective or disconnected indoor air sensor (RAT)
O
Defective or disconnected coil sensor (ICT)
O
Defective or disconnected compressor discharge temperature sensor (CDT) Contact service centre
= LED on
= flashing LED
Trouble: the air conditioner does not run at all.
Possible cause:
1. Power failure.
2. Leakage breaker tripped.
3. Line voltage is too low.
4. Operation button is OFF.
5. Batteries in remote control unit have run down.
Remedy:
1. Restore power.
2. Contact service center.
3. Consult your electrician or dealer.
4. Press the button again.
5. Replace batteries.
Trouble: Compressor runs but soon stops.
Possible cause:
1. Obstruction in front of condenser coil.
Remedy:
1. Remove obstruction.
Trouble: Poor cooling performance.
Possible cause:
1. Dirty or clogged air filter.
2. Heat source or many people in room.
3. Doors and/or windows are open.
4. Obstacle near air intake or air discharge port.
5. Thermostat is set too high.
Remedy:
1. Clean air filter to improve airflow.
2. Eliminate heat source if possible.
3. Shut them to keep the heat or cold out.
4. Remove it to ensure good airflow.
5. Set the temperature lower.
Trouble: Clicking sound is heard from the air conditioner.
Possible cause:
1. Any plastic parts may expand or shrink due to a sudden
temperature change. In this event, a clicking sound may
occur.
Remedy:
1. This is normal, and the sound will disappear when an
even temperature is settled.
POSSIBLE CAUSE
14
REMEDY
Select an available mode
Contact service centre
Contact service centre
Contact service centre
Contact service centre
Contact service centre
Contact service centre
Contact service centre