Appendix B
Troubleshooting
Error Message %MWAM_FILESYSTEM-3-FC_INVALID_DIR_REQ: Cannot read or write complete
%s file system.
Error Message %MWAM_FILESYSTEM-3-FC_DIR_IS_FULL: Cannot add %s to file system,
directory is full.
Error Message %MWAM_FILESYSTEM-6-BOOTFLASH_BUSY: Cannot access bootflash,
filesystem is busy

Flash Error Messages

Error Message %MWAM_FLASH-3-ERR: "%s"
Error Message %MWAM_FLASH-3-OTHER_CPU_RELOAD: "%s"
OL-7469-04
Explanation
A CLI command attempted to copy or overwrite the full file system.
Copy from or to an individual file.
Recommended Action
The file system directory holds a limited number of entries, and an attempt was made to
Explanation
add a new file when the directory was already full. This can happen even when the file system still
contains free space.
Delete an existing file or FORMAT the file system.
Recommended Action
The MWAM bootflash does not support reading and writing at the same time. The
Explanation
message means that bootflash is being accessed by some other operation, like copy, dir, format or
squeeze.
Recommended Action
Try the bootflash operation again after other operations have completed.
An error occurred while programming/erasing the BootFlash
Explanation
Recommended Action
Copy the error message exactly as it appears on the console or in the system
log. Research and attempt to resolve the error using the Output Interpreter
"OUTPUT_INTERPRETER." Also perform a search of the Bug Toolkit "BUG_TOOLKIT." If you
still require assistance, open a case with the Technical Assistance Center via the Internet
"TAC_CASE_OPEN," or contact your Cisco technical support representative and provide the
representative with the gathered information.
Explanation
The other CPU within this complex is reloading, flash programming operation can not
proceed.
Recommended Action
Wait for the system to complete the reload operation.