ACU-RITE SENC 150 Manuel d'instructions - Page 11
Parcourez en ligne ou téléchargez le pdf Manuel d'instructions pour {nom_de_la_catégorie} ACU-RITE SENC 150. ACU-RITE SENC 150 12 pages. Chevalier fsg-2a 1224 surface grinder cross feed “x” axis
Également pour ACU-RITE SENC 150 : Manuel d'installation (8 pages), Manuel de référence (20 pages), Manuel d'installation (4 pages), Manuel d'installation (6 pages)
SENC 150 Reading Head Replacement Instructions
Connecting the encoder
Route the cables with slack loops
to allow for axis motion.
Secure excess cable by fastening
with clips or ties.
Attach the linear encoder connectors
to the readout.
Checking the electrical shielding
Connect a ground wire from the
terminal on the back of the readout to
the machine or earth ground.
Attach a ground wire from the machine
to a solid earth ground.
Check shielding by measuring the re-
sistance between connector housing
and scale unit.
Desired value: 1 Ω max.
9 Checking the mounting
11