SENC 150 Reading Head Replacement Instructions
Connecting the encoder
 Route the cables with slack loops
to allow for axis motion.
 Secure excess cable by fastening
with clips or ties.
 Attach the linear encoder connectors
to the readout.
Checking the electrical shielding
 Connect a ground wire from the
terminal on the back of the readout to
the machine or earth ground.
 Attach a ground wire from the machine
to a solid earth ground.
 Check shielding by measuring the re-
sistance between connector housing
and scale unit.
Desired value: 1 Ω max.

9 Checking the mounting

11