SENC 150 Reading Head Replacement Instructions
Installing alignment brackets
 Attach the alignment brackets provided by inserting the top
ears into the bottom grooves in the scale case.
 Numbers and letters on reading head casting and alignment
brackets correspond when assembled.
Slide brackets against
reading head snap into place.
Installing end cap(s)
spring clip
Insert brackets at 45°
and twist to lock in scale grove.
Determining cable direction
 Determine cabel exit direction before mounting the encoder.
 To change the cable exit direction, remove the cover plate
and rotate it 180°.
K1 - cable exit right side
1
1
K2 - cable exit left side
1
1

7 Preparing the remounting

Do not pull out the PCB!
1
T-10 torx screw
Do not clamp the wires!
1
T-10 torx screw
max. 70 Ncm!