ACU-RITE SENC 150 사용 설명서 - 페이지 9

{카테고리_이름} ACU-RITE SENC 150에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. ACU-RITE SENC 150 12 페이지. Chevalier fsg-2a 1224 surface grinder cross feed “x” axis
ACU-RITE SENC 150에 대해서도 마찬가지입니다: 설치 매뉴얼 (8 페이지), 참조 매뉴얼 (20 페이지), 설치 매뉴얼 (4 페이지), 설치 매뉴얼 (6 페이지)

SENC 150 Reading Head Replacement Instructions
Installing alignment brackets
 Attach the alignment brackets provided by inserting the top
ears into the bottom grooves in the scale case.
 Numbers and letters on reading head casting and alignment
brackets correspond when assembled.
Slide brackets against
reading head snap into place.
Installing end cap(s)
spring clip
Insert brackets at 45°
and twist to lock in scale grove.
Determining cable direction
 Determine cabel exit direction before mounting the encoder.
 To change the cable exit direction, remove the cover plate
and rotate it 180°.
K1 - cable exit right side
1
1
K2 - cable exit left side
1
1

7 Preparing the remounting

Do not pull out the PCB!
1
T-10 torx screw
Do not clamp the wires!
1
T-10 torx screw
max. 70 Ncm!
9