SENC 150
Longitudinal Installation ...
*
Supplied with encoder hardware
**Supplied with center support hardware
Mounting Information...
These are application instructions for mounting the
longitudinal "X" axis SENC 150 encoder.
Before proceeding:
Please read the instructions completely.
Mount X axis prior to installing the cross feed.
Insure that the correct length encoder is being used
for the total axis travel.
Keep the reading head centered during installation.
Clean the mounting surfaces.
Save the alignment brackets with the Encoder
Reference Manual after installation is completed.
First Steps ...
Machine
Move the table to its center of travel.
Mark the axis so that it can be re-centered easily.
Move the saddle completely forward on the knee.
P.N. 385072-208 Ed B 2/06
Encoder Installation Manual For: Vertical Knee Mill
Stop
Reading head bracket
* 1/4-20 x 1" BHCS (2)
Encoder
Unpack encoder in a safe, convenient location.
Do not remove the reading head alignment
brackets until instructed.
Center reading head ...
Slide the reading head and brackets along the scale
case until the center marks on the scale case and
reading head are aligned.
Installation Manual 385072-38
1
Longitudinal X Axis on Rear of Table
5/16-18 x 3/4" SHCS
Encoder
** Center support
* 8-32 x 5/8" SHCS
(2)
1/4" Heavy flat washer
(2) .09" thick
Alignment bracket (2)
* M6 Flat washer (2)
.017" thick
** M6 Flat washer
.017" thick
** 1/4-20 x 3/4" BHCS
1/4-20 x 3/4" BHCS (2)
Align
center
marks
Acu-Rite Companies Inc.