Cisco C880 M4 Manuel d'utilisation - Page 40
Parcourez en ligne ou téléchargez le pdf Manuel d'utilisation pour {nom_de_la_catégorie} Cisco C880 M4. Cisco C880 M4 48 pages. System event log collection
Également pour Cisco C880 M4 : Manuel de supplément de service (27 pages), Manuel d'installation du matériel (23 pages), Manuel de démarrage rapide (2 pages), Manuel de mise à jour du micrologiciel (5 pages)

Drives "dead" on System Start
9.1.7.
Incorrect cabling
Ensure that the cabling correspond to the original status.
Configuration of the RAID controller incorrect
Call up the RAID utility from the configuration disk or from the controller BIOS of the RAID controller, and
correct the settings for the drives.
You will find further notes in the RAID controller documentation.
9.1.8.
RAID Controller Indicates the Added Drive to be Incorrect
This error message can have the following cause:
RAID controller not configured for the drive
Installation was occurred with the system switched off.
Configure the RAID controller retroactively for the drive. You will find information on this topic in the
RAID controller documentation
or
Re-install the drive with the system switched ON.
If the drive is still found to be incorrect, it must be replaced (see
on page
25).
40
Operating Manual
9.1Problem Solutions and Tips
section "
Hot-Plug for Hard Disk Drives
"